Does lk410 report over range?
Page 207 If the over-limit alarm enabled and over range occurred at the same time, LK410 reports over range. Figure 7-20 LK410 Over-limit Alarm Diagram When an input channel signal beyond the limit: Beijing HollySys Intelligent Technologies Co., Ltd. All Rights Reserved... It is not read by each scan cycle.
What is the user parameter length of lk511 module?
The user parameter length of the LK511 module is up to 22 bytes, used to set change range, fault mode output, and fault mode output value, channel diagnosis enable. Table 7-80 Table of LK511 User Parameters Parameter Name Meaning Value Beijing HollySys Intelligent Technologies Co., Ltd. All Rights Reserved...
What is lk141 a module?
Chapter 5 Master Control Unit 5.6 LK141-A Empty Module LK141 is an empty module of LK series controller, which only has a structure part, without circuit board, and be used to cover unused empty slots on the backboard. Figure 5-29 LK141-A Module Schematic Diagram...
What is lk441 module?
Page 264 The LK441 module is capable of limit exceeded alarm. It can set the alarm boundary line flexibly according to different industrial fields, detects field temperature signal changes, and timely gives an limit exceeded alarm, thus well improving security in industrial control. Beijing HollySys Intelligent Technologies Co., Ltd.
How does lk234 module communicate with the controller?
LK234 module communicates with the controller through two-way redundant HOLLITCP, and communicates with DP slave through two-way redundant Profibus-DP. LK234 module as a slave station in the HOLLITCP protocol side and as the master in the Profibus-DP protocol side.
How many slots does a lk130 module have?
It works with controllers and I/O modules of the new-generation LK Series. The module has 4 slots in total, which can be connected to power modules, CPU modules and communication extension modules. See Figure 5-2 for the internal structure schematic diagram of the LK130 module.
Related Contents
- Smart energy storage cabinet parameter settings
- Where is the energy storage solenoid valve of the lk die casting machine located
- Parameter requirements for large-scale energy storage batteries
- Solar energy storage battery parameter table
- Default energy storage device in settings
- Energy storage battery charging parameter adjustment plan
- Photovoltaic energy storage equipment technical parameter table
- Working principle of flywheel inertial energy storage
- Pure supercapacitor energy storage station case
- Singularity energy distributed modular energy storage
- Liechtenstein energy storage project